Piezoelectric force sensor SlimLine, ring force transducer (Fz 36 kN / 8.09 klbf), configurable cable length / 9135C29

Piezoelectric force sensor SlimLine, ring force transducer (Fz 36 kN / 8.09 klbf), configurable cable length
9135C29
18038063
  • Piezoelectric force sensor SlimLine with a measuring range of Fz: 0 ... 36 kN (8.09 klbf)
  • Dimensions D x d x H: 24 x 10.1 x 3.5 mm
  • Connector: KIAG 10-32 pos. int.
  • Cable length: 0.1 to 2 m
 
 
Preloaded sensorNoMeasuring range0 … 36 kNMaximum measuring range36 kNForce sensor typeSingle axis force sensorRecommended preloading force7.2 kNMaximum bending moment Mxy (single load)62.2 NmAxial stiffness8.2 kN/μmBending stiffness4.815 kNm/°Shear stiffness3 kN/μmTorsional stiffness4.812 kNm/°Insulation resistance≥10^13 ΩMass7 gCase materialDIN 1.4542Customized cable length0.1 … 2 mNominal sensitivity–4.3±0.3 pC/NOverload42 kNTemperature coefficient of sensitivity–0.02 %/°COperating temperature range-20 … 120 °CLinearity≤±1 %FSOOutput signal typeCharge (Piezoelectric, PE)Degree of protection EN 60529IP65ApplicationsSpot welding process monitoring, NVH Testing
Piezoelectric force sensor, also known as piezoelectric ring force transducer, with extremely flat design for precisely measuring compression forces. Maximum resolution capacity, high stiffness and extremely compact dimensions enable ideal installation in mechanical structures. The case is hermetically sealed and has an integrated, splash-proof connecting cable with connector. This piezoelectric force sensor SlimLine is supplied uncalibrated and must be calibrated in situ after mounting for absolute measurements.The force Fz to be measured acts on the piezoelectric force sensor via the preloaded or mounting structure and produces a charge that is directly proportional to the force. This is measured by an electrode integrated in the ring force transducer and fed to the charge amplifier via the integrated cable. Because of their exceptional stiffness, SlimLine sensors are especially well suited for measuring dynamic forces. Cyclic measurements or measurements over several minutes are also possible, however. The sensor is especially well suited for measuring forces in shunt mode. This means that the sensor is embedded and preloaded in a structure. As a result, it is loaded with only part of the process force. Its especially small size is ideally suited for installation in structures such as force plates, fitting strips and tools. The sensor is used in industrial production processes in which forces are monitored or measured. Used in combination with a ControlMonitor, the sensor is ideal for quality control and monitoring.
 
 
Laboratory charge amplifiers, multi-channel, low noise, measuring ranges ±2 to ±2200000 pC, freq. range ≈0 … 200 kHz
5080A
5080A      
 
Laboratory charge amplifier, multi-channel, low noise, measuring ranges from ±2 to ±2200000 pC