Dinamómetro Multicomponente, 5 kN, Cubierta 100x170 mm / 9257B

Dinamómetro Multicomponente, 5 kN, Cubierta 100x170 mm
9257B
18007542
  • Dinamómetro multicomponente piezoeléctrico con fuerzas máximas Fx, Fy, Fz ±5 kN
  • Cubierta 100x170 mm
  • Frecuencia natural fn (x), fn (y), fn (z) 3,5 kHz
  • Conector Fischer de brida de 9 polos
Bajo pedido
Bajo pedido
Inicie sesión en myKistler para ver los precios
Measuring ranges
Minimum measuring range [kN]
-5 kN
Maximum measuring range [kN]
10 kN
Product type
Force sensor type
A dynamometer is a force plate measuring forces and moments.
Multicomponent dynamometer
Preloaded sensor
Preloaded sensors are already calibrated and therefore ready-to-use. Non-preloaded sensors are smaller.
Yes
Mechanical properties
Stiffness Cx [kN/μm]
1 kN/μm
Stiffness Cy [kN/μm]
1 kN/μm
Stiffness Cz [kN/μm]
2 kN/μm
Overload Fx [kN]
-7.5, 7.5 kN
Overload Fy [kN]
-7.5, 7.5 kN
Overload Fz [kN]
-7.5, 15 kN
Metrological characteristics
Linearity
Linearity represents the maximum deviation/error between ideal and actual output signal characteristics in relation to the measurand in a specific measuring range. It is expressed in percentage of the range of measurement signal (Full Scale Output).
≤±1 %FSO
Hysteresis
≤0.5 %FSO
Threshold
<0.01 N
Electrical properties
Output signal type
Charge (Piezoelectric, PE)
Capacitance
≈220 pF
Minimal insulation resistance
10^13 Ω
Ground Insulation
>10^8 Ω
Influence quantities
Sensitivity
Fx: -7.5 pC/N, Fy: -7.5 pC/N, Fz: -3.7 pC/N
Dynamical properties
Natural frequency Fx
Frequency of free (not forced) oscillations of the entire sensor. In practice the (usually lower) natural frequency of the entire mounted system governs the frequency behavior.
3.5 kHz
Natural frequency Fy
Frequency of free (not forced) oscillations of the entire sensor. In practice the (usually lower) natural frequency of the entire mounted system governs the frequency behavior.
3.5 kHz
Natural frequency Fz
Frequency of free (not forced) oscillations of the entire sensor. In practice the (usually lower) natural frequency of the entire mounted system governs the frequency behavior.
3.5 kHz
Certificates and Standards
Degree of protection EN 60529
IP67
Operation and installation
Operating temperature range
0 … 70 °C
Clamping area
100 mm x 170 mm
Cable properties
Cable included
No cable included
Interfaces
Connector type
Fischer 104 9-pole neg.
Dimensions and materials
Weight
7.3 kg
Se trata de un dinamómetro piezoeléctrico de tres componentes para medir los tres componentes ortogonales de una fuerza. El dinamómetro tiene una gran rigidez y, en consecuencia, una elevada frecuencia natural. Su alta resolución permite medir los cambios dinámicos más pequeños en grandes fuerzas.
Carga
Carga