Kistler propose des capteurs de haute précision et des solutions d'acquisition des données non intrusives, embarquées dans tous les types de mannequins. Notre logiciel rend la gestion et l'exécution des crash-tests rapide et souple. Kistler vous permet d'obtenir des mesures fiables et précises des accélérations, des moments et des forces.

Contact
Kistler France
Sales Representative

Tri-axial Thoracic Spine Load Cell for the BioRID (BR) Dummy

Type M56423

The tri-axial sensor is designed to measure the forces Fx, Fz and moment My in the thoracic spine area.

  • Measuring range 5,0 kN, 5,0 kN and 125 Nm
  • Low linearity error and hysteresis
  • Polarities according to SAE J211/1

Cellule de charge tri-axiale pour col du fémur sur mannequin WorldSID WS-5

Type M53923

Le capteur tri-axial est conçu pour mesurer les forces Fx, Fy, Fz dans le col du fémur.

  • Plage de mesure 10 kN, 25 kN, 10 kN
  • Erreurs et hystérésis à faible linéarité
  • Polarités selon SAE J211/1
  • .

Cellule de charge tri-axiale pour col du fémur sur mannequin WorldSID WS-50

Type M53903

Le capteur tri-axial est conçu pour mesurer les forces Fx, Fy, Fz dans le col du fémur.

  • Plage de mesure 10 kN, 25 kN, 10 kN
  • Erreurs et hystérésis à faible linéarité
  • Polarités selon SAE J211/1

Cellule de charge pour pubis uni-axiale sur mannequins WorldSID

Type M50241

Le capteur uni-axial est conçu pour mesurer la force Fy dans la région pubienne.

  • Plage de mesure 12 kN
  • Erreurs et hystérésis à faible linéarité
  • Polarités selon SAE J211/1
  • .

CC sacro-iliaque de douze axes

Type M5670B

Le capteur à 12 axiaux mesure la force et le couple dans le sacrum du mannequin WorldSID. Il présente une déviation et une hystérésis à faible linéarité.

CC lombaire six-axiale

Type M56826

Le capteur six-axial mesure la force et le couple dans la colonne lombaire du mannequin WorldSID. Il présente une déviation et une hystérésis à faible linéarité.

Cellule de charge tri-axiale pour épaule sur mannequin WorldSID WS-5

Type M53653

Le capteur tri-axial est conçu pour mesurer les forces Fx, Fy, Fz dans l'épaule.

  • Plage de mesure 4 kN, 5 kN, 4 kN
  • Erreurs et hystérésis à faible linéarité
  • Polarités selon SAE J211/1
  • .

Cellule de charge tri-axiale pour épaule sur mannequin WorldSID WS-50

Type M53643

Le capteur tri-axial est conçu pour mesurer les forces Fx, Fy, Fz dans l'épaule.

  • Plage de mesure 5 kN, 10 kN, 5 kN
  • Erreurs et hystérésis à faible linéarité
  • Polarités selon SAE J211/1
  • .

Cellule de charge sixaxiale pour partie supérieure et inférieure du cou sur mannequins WorldSID

Type M55556

Le capteur six-axial est conçu pour mesurer les forces Fx, Fy, Fz et les moments Mx, My, Mz dans le haut et le bas du cou.

  • Plage de mesure 10 kN, 10 kN, 12 kN et 300 Nm, 300 Nm, 200 Nm
  • Erreurs et hystérésis à faible linéarité
  • Polarités selon SAE J211/1
  • .

Enregistreur de données, 144 canaux

Type DTI304.12 / DTI304.08 / DTI304.04

L'enregistreur de données intégré au mannequin peut se raccorder à 144 canaux de mesure et consigne les valeurs numériques pendant un essai de choc. La transmission des données se fait par câble système.

Data Recorder - In-Dummy Data Acquisition Modul

Type DTI375.TH

The data recorder the Thor-M dummy records digitized measuring values up to 288 measuring channels during a crash test. The data are stored centrally and are transmitted via system cable subsequently.

Uniaxial Face Load Cell for the Thor-M (TH) Dummy

Type M55991

The uni-axial sensor is designed to measure the force Fx in the face area.

  • Measuring range 4.5 kN
  • Low linearity error and hysteresis
  • Polarities according to SAE J211/1

Uniaxial Skull Spring Load Cell for the Thor-M (TH) Dummy

Type M55191

The uni-axial sensor is designed to measure the force Fy in the skull spring area.

  • Measuring range 6.7 kN
  • Low linearity error and hysteresis
  • Polarity according to SAE J211/1

Six-axial Upper Neck Load Cell for the Thor-M (TH) Dummy

Type M55596

The six-axial sensor is designed to measure the forces Fx, Fy, Fz and moments Mx, My, Mz in the upper neck area.

  • Measuring range 8.9 kN, 8.9 kN, 13.3 kN and 284 Nm
  • Low linearity error and hysteresis
  • Polarities according to SAE J211/1

Six-axial Lower Neck Load Cell for the Thor-M (TH) Dummy

Type M55696

The six-axial sensor is designed to measure the forces Fx, Fy, Fz and moments Mx, My, Mz in the lower neck area.

  • Measuring range 13.3 kN, 13.3 kN, 13.3 kN and 452 Nm, 452 Nm, 226 Nm
  • Low linearity error and hysteresis
  • Polarities according to SAE J211/1

Four-axial Clavicle Load Cell for the Thor-M (TH) Dummy

Type M53894

The four-axial sensor is designed to measure the forces Fx, Fz (2x) in the Clavicle area.

  • Measuring range 2.0 kN
  • Low linearity error and hysteresis
  • Polarities according to SAE J211/1

Five-axial Thoracic Spine Load Cell for the Thor-M (TH) Dummy

Type M56495

The five-axial sensor is designed to measure the forces Fx, Fy, Fz and moments Mx, My in the thoracic spine area.

  • Measuring range 13.4 kN, 13.4 kN, 17.8 kN and 680 Nm, 900 Nm
  • Low linearity error and hysteresis
  • Polarities according to SAE J211/1

Biaxial Illiac Wing (ASIS) Load Cell for the Thor-M (TH) Dummy

Type M52292

The bi-axial sensor is designed to measure the force Fz and moment My in the illiac wing (ASIS) area.

  • Measuring range13.0 kN and 325 Nm
  • Low lineraty error and hysteresis
  • Polarities according to SAE J211/1

Triaxial Acetabulum Load Cell for the Thor-M (TH) Dummy

Type M52893

The tri-axial sensor is designed to measure the forces Fx, Fy, Fz in the acetabulum area.

  • Measuring range 22.2 kN, 13.3 kN, 13.3 kN
  • Low linearity error and hysteresis
  • Polarities according to SAE J211/1

Five-axial Upper Tibia Load Cell for Thor-M (TH) and Thor-LX Dummy

Type M55295

The five-axial sensor is designed to measure the forces Fx, Fy, Fz and moments Mx, My in the upper tibia area.

  • Measuring range 11,0 kN and 400 Nm
  • Low linearity error and hysteresis
  • Polarities according to SAE J211/1

Five-axial Lower Tibia Load Cell for the Thor-M (TH) and Thor-LX Dummies

Type M55395

The five-axial sensor is designed to measure the forces Fx, Fy, Fz and moments Mx, My in the lower tibia area.

  • Measuring range 11.0 kN and 400 Nm
  • Low linearity error and hysteresis
  • Polarities according to SAE J211/1

Uniaxial Achilles Tendon Load Cell for the Thor-M (TH) Dummy

Type M55491

The uni-axial sensor is designed to measure the force Fy in the achilles tendon area.

  • Measuring range 4.5 kN
  • Low linearity error and hysteresis
  • Polarities according to SAE J211/1

Accél. piézorés. uni-axial.

Type M0064C00

Le capteur d'accélération est basé sur un capteur MEMS piézorésistif évolué qui assure des dynamiques et une stabilité extraordinaires.