Triaxial force sensor, ring force transducer, Fx, Fy, Fz (Fz ±3 kN / ±674 lbf) / 9017C

Triaxial force sensor, ring force transducer, Fx, Fy, Fz (Fz ±3 kN / ±674 lbf)
9017C
18013433
  • Triaxial piezoelectric force sensor with measuring ranges Fx, Fy: -1.5 ... 1.5 kN and Fz: -3 ... 3 kN (±674 lbf)
  • High shear force range due to electrically insulating ceramic contact surfaces
  • Nominal sensitivity Fz: -11 pC/N
  • Connection: V3 neg.
 
 
Preloaded sensorNoMeasuring range-3 … 3 kNMaximum measuring range3 kNForce sensor typeTriaxial force sensorCalibrated range Fz0 … 12.5 kNOverload Fx, Fy–1.8/1.8 kNRange Fx, Fy-1.5 … 1.5 kNRange Fz-3 … 3 kNCrosstalk Fx <-> Fy±2.5%Overload Fz–3.6/3.6 kNTorsion stiffness317 Nm/°Calibrated range Fx0 … 1.5 kNCalibrated range Fy0 … 1.5 kNStandard preload Fv9.5 kNSensitivity Fx, Fy≈–25 pC/NLinearity, each axis±0.5 %FSOAxial stiffness1.471 kN/μmBending stiffness352 Nm/°Shear stiffness0.308 kN/μmCapacitance, each channel35 pFGround insulated>10^8 ΩPermissible moment loading Mx, My-6.6 … 6.6 NmPermissible moment loading Mz-6.6 … 6.6 NmConnecting plugV3 neg.Threshold<0.01 NOperating temperature range-40 … 120 °COutput signal typeCharge (Piezoelectric, PE)Degree of protection EN 60529IP68Insulation resistance>10^13 ΩWeight14 gApplicationsNVH Testing
Triaxial force sensor for measuring forces in any given direction, regardless of the point of load application. This triaxial ring force transducer quantifies all three components of any applied force in highest resolution. The triaxial force sensors of the 90x7 and 90x8 lines are absolutely identical except for the orientation of the coordination system. The output of the piezoelectric triaxial force sensor is an extremely linear electrical charge over their entire measuring range – this load is directly proportional to the applied force. The ring force transducer housing contains one quartz ring per force component and can be precisely aligned and mounted due to its flattened sides. The simple and vibration-resistant design of the sensor is extremely stiff and, with its uniquely high natural frequency, enables the measurement of highly dynamic force processes. With two ceramic discs on the contact surfaces, a high coefficient of friction is guaranteed on the one hand and massinsulated installation in the machine structure is possible on the other. The magnitude of the measuring range of the shear forces in the x- and y-directions depends directly on the preload in the z direction and the resulting axial static friction. The signals are picked up via the design-protected, 3-pole connector plug V3 neg., which uses a positioning aid to ensure the exact assignment of the connector pins and protects against twisting.
Handout
Inglese
pdf
 
Manuale
3-Komponenten- Kraftsensor Typ 9027C, 9028C, 9026C4
Tedesco
pdf
 
Piezoelektrischer 3-Komponenten- Kraftsensor Typ 9017C, 90 18C, 9016C4
Tedesco
pdf
 
Piezoelectric triaxial force sensor Type 90x7C, 90x8C, 90x6C4
Inglese
pdf
 
Scheda tecnica
Tedesco
pdf
 
Spagnolo
pdf
 
Giapponese
pdf
 
Tedesco
pdf
 
Inglese
pdf
 
Giapponese
pdf
 
Giapponese
pdf
 
Giapponese
pdf
 
Giapponese
pdf
 
Giapponese
pdf
 
Tedesco
pdf
 
Inglese
pdf
 
Giapponese
pdf
 
Cinese
pdf
 
Inglese
pdf
 
 
 
Preloading sets for triaxial and big force sensors (90x7C, 90x8C, 9081, 9091)
PL-Sets
9460SP      
 
Preloading set for triaxial force sensors of Types 9017C, 9018C and 9016C4, variable screw length
Connecting cables (TPC black) for triaxial force sensors with V3 neg. connector
1698-3TPC
1698AN4sp      
 
Connecting cable for triaxial force sensors, V3 90°, 3 x KIAG 10-32 pos., exit angle 270°, down
1698AN3sp      
 
Connecting cable for triaxial force sensors, V3 90°, 3 x KIAG 10-32 pos., exit angle 180°, left
Laboratory charge amplifiers, multi-channel, low noise, measuring ranges ±2 to ±2200000 pC, freq. range ≈0 … 200 kHz
5080A
5080A      
 
Laboratory charge amplifier, multi-channel, low noise, measuring ranges from ±2 to ±2200000 pC