Piezoelectric load cell, force transducer (Fz ±48 kN / ±10.8 klbf) / 9351C

Piezoelectric load cell, force transducer (Fz ±48 kN / ±10.8 klbf)
9351C
18037814
  • Piezoelectric force transducer with a measuring range of Fz: -48 … 48 kN (±10.8 klbf)
  • Dimensions D x H: 41 x 72 mm
  • Female screw thread: M20x2.5
  • Connector: KIAG 10-32 neg.
 
 
Preloaded sensorYesMeasuring range-48 … 48 kNMaximum measuring range48 kNForce sensor typeSingle axis force sensorCalibrated range 10 … 48 kNCalibrated range 20 … 0.48 kNCalibrated range 30 … -48 kNMaximum force±52.8 kNNominal force±48 kNMaximum bending moment (Fz=0)312 NmTemperature sensitivity, sensitivity change (-40°C … 120°C, Tref = 25°C)±1.5 %Natural frequency (free-free) f0fz27.9 kHzAxial stiffness1756 kN/μmBending stiffness3.105 kNm/°Shear stiffness0.229 kN/μmTorsional stiffness2.269 kNm/°Sensor capacitance93±7 pFGround insulation resistance≥100 MΩInsulation resistance≥10^13 ΩSensitivity–3.9±0.3 pC/NOperating temperature range-40 … 120 °CLinearity±0.5 %FSOOutput signal typeCharge (Piezoelectric, PE)Weight480 gApplicationsIn- and End-of-Line Testing for Production processes
A piezoelectric load cell, also known as force transducer or force link, measures dynamic or quasistatic forces, both tensile and compression. This load cells contains a piezoelectric ring force transducer of the 90x1C sensor family which is preloaded and calibrated, thus ready to use immediately. Sensors in the 93x1C load cell family are the easiest way to measure forces piezoelectrically without the need for sophisticated installation and calibration. These force transducers are factory calibrated and preloaded to measure both tension and compression forces. The load cell is ready to measure within minutes and provide accurate data from dynamic or quasistatic processes. In addition, these force transducers have been installed in an electrically isolated manner, so that ground loops are largely eliminated.
 
 
High-insulating connecting cables, KIAG 10-32 pos. - TNC pos., PFA green
1633C
1633CSP      
 
High-insulating connecting cable, KIAG 10-32 pos. - TNC pos., PFA green, customer-specific length
Connecting cables for piezoelectric sensors, very sturdy, KIAG 10-32 pos. - KIAG 10-32 pos. or BNC pos.
1900A21
1900A21A12SP      
 
Connecting cable for piezoelectric sensors, very sturdy, KIAG 10-32 pos. - BNC pos., length 0.3 to 20 m
1900A21A11SP      
 
Connecting cable for piezoelectric sensors, very sturdy, KIAG 10-32 pos. - KIAG 10-32 pos., length 0.3 to 20 m
Laboratory charge amplifiers, multi-channel, low noise, measuring ranges ±2 to ±2200000 pC, freq. range ≈0 … 200 kHz
5080A
5080A      
 
Laboratory charge amplifier, multi-channel, low noise, measuring ranges from ±2 to ±2200000 pC