Piezoelectric sensor, transverse strain measuring pin (8 mm, M3 neg., 3 m cable) / 9240AB3

Piezoelectric sensor, transverse strain measuring pin (8 mm, M3 neg., 3 m cable)
9240AB3
18030745
  • Piezoelectric sensor, measuring range (transversal): 0 … 500 με
  • Nominal sensitivity: –9.5 pC/με
  • Dimensions DxL (mm): 8x14.5
  • Output connection: M3x0.35 pos. with high temperature cable (3 m)
 
 
Measuring range (µε)0 … 500 μεCapacitance338 pFOverload with preload 510N850 μεRange with preload 510N0 … 500 μεOverload with preload 850N700 μεRange with preload 850N–140 ... 350Overload with preload 1250N570 μεRange with preload 1190N-285 … 210 μεMaximal acceleration sensitivity in measuring direction 10g RMS0.02 με/gForce sensitivity for preload≈–4 pC/NRepeatability of sensitivity after demounting and remounting±2%Sensitivity in test object≈–9,5 pC/μεThreshold in test object0.005 μεGround insulation≥10^8 ΩStrain sensor typeTransversal strain measuring pinOperating temperature range-40 … 200 °CHysteresis≤1,5 % FSOLinearity≤±1 % FSOOutput signal typeCharge (Piezoelectric, PE)Degree of protection EN 60529IP64Insulation resistance>10^13 ΩWeight34 g
 
 
Laboratory charge amplifiers, multi-channel, low noise, measuring ranges ±2 to ±2200000 pC, freq. range ≈0 … 200 kHz
5080A
5080A      
 
Laboratory charge amplifier, multi-channel, low noise, measuring ranges from ±2 to ±2200000 pC