Piezoelectric Press Force load cell, press force transducer, Fz max 0 … 20 kN / 9323A

9323A
9323A
18007665
  • Preloaded and calibrated press force transducer, ready to measure immediately
  • Calibrated ranges Fz: 0 … 0,2 kN, 0 … 2 kN, 0 … 20 kN
  • Sensitivity: ≈ –3,9 pC/N
  • Dimensions DxH: 20x26 mm
 
 
Preloaded sensorYesMeasuring range0 … 20 kNMaximum measuring range20 kNForce sensor typeStandard force sensorCalibrated measuring range0 … 20 kN (Fz 100%)Maximum shear force Fx, Fy (Fz = 0)0.62 kNMaximum tension force0 … -2 kNMaximum torque Mz (Fx = 0, Fy = 0, Fz = 0)5 NmOverload Fz24 kNPreloading force Fv8.5 kNMaximum bending moment Mx,y at Fz = 0%23 NmMaximum bending moment Mx,y at Fz = 100%0.9 NmCrosstalk Fx,y -> Fz≤±0.03 N/NCrosstalk Mx,y -> Fz≤±0.5 N/NmRepeatability0.02 %Natural frequency fn(Fz)>72 kHzRigidity Cz (Fz)≈1.2 kN/μmCapacity C≈29 pFCase materialDIN 1.4542Temperature coefficient of sensitivity0.05 %/°CSensitivity–3.9 pC/NOperating temperature range-40 … 120 °CLinearity≤±0.5 %FSOOutput signal typeCharge (Piezoelectric, PE)Degree of protection EN 60529IP67 (with welded sensor), IP65 (with connected cable)Insulation resistance at 20 °C≥50^13 ΩWeight47 gApplicationsIn- and End-of-Line Testing for Production processes
This force transducer of the Press Force series is ideal for measuring both dynamic and quasistatic forces. The factory preloading and adaptability of these practical designs ensure readiness for immediate use. The Press Force load cell is based on the piezoelectric measuring principle. The force acting on the quartz element generates at the output of the sensor a proportional electric charge, which is converted by the series-connected measuring amplifier into a process signal suitable for evaluation (typically 0 ... 10 V). Depending on the type of sensor, tension forces of up to 16 % of the compression force range can also be measured. Although uncalibrated, these ranges is often used for detecting tool withdrawal forces, for example after press-fit processes.
Data sheet
German
pdf
 
English
pdf
 
Japanese
pdf
 
Chinese
pdf
 
Manual
Press Force Sensor
English
pdf
 
Press Force Sensor
German
pdf
 
 
 
undefined
High-insulating connecting cables, KIAG 10-32 pos. - TNC pos., PFA green
1633C
1633CSP      
 
High-insulating connecting cable, KIAG 10-32 pos. - TNC pos., PFA green, customer-specific length
undefined
Connecting cables for piezoelectric sensors, very sturdy, KIAG 10-32 pos. - KIAG 10-32 pos. or BNC pos.
1900A21
1900A21A12SP      
 
Connecting cable for piezoelectric sensors, very sturdy, KIAG 10-32 pos. - BNC pos., custom, 0.3 to 20 m
1900A21A11SP      
 
Connecting cable for piezoelectric sensors, very sturdy, KIAG 10-32 pos. - KIAG 10-32 pos., custom, 0.3 to 20 m
undefined
Laboratory charge amplifiers, multi-channel, low noise, measuring ranges ±2 to ±2200000 pC, freq. range ≈0 … 200 kHz
5080A
5080A      
 
Laboratory charge amplifier, multi-channel, low noise, measuring ranges from ±2 to ±2200000 pC
undefined
Connecting cables for piezoelectric sensors, KIAG 10-32 pos. - KIAG 10-32 pos.
1635C
1635CSP      
 
Connecting cable for piezoelectric sensors, KIAG 10-32 pos. - KIAG 10-32 pos., custom length, 0.1 to 50 m
undefined
Connecting cables for piezoelectric sensors, KIAG 10-32 pos. int. - BNC pos.
1939A
1939ASP      
 
Connecting cable for piezoelectric sensors, KIAG 10-32 pos. int. - BNC pos., custom length 0.1 to 20 m
undefined
Connecting cables for piezoelectric sensors, KIAG 10-32 pos. int. - TNC pos.
1941A
1941ASP      
 
Connecting cable for piezoelectric sensors, KIAG 10-32 pos. int. - TNC pos., custom length, 0.1 to 50 m