Connecting cable for piezoelectric sensors, KIAG 10-32 pos. int. - TNC pos., 0.5 m / 1941A0,5

Connecting cable for piezoelectric sensors, KIAG 10-32 pos. int. - TNC pos., 0.5 m
1941A0,5
18026139
  • Length: 0.5 m
  • Temperature range: –55 to +200°C
  • Sensor connection: KIAG 10-32 pos. int (IP65)
  • Amplifier connector: TNC pos. (IP65)
Upon request
On request
Mechanical properties
Bending radius [mm]
5 mm
Certificates and Standards
Degree of protection EN 60529
IP65, IP40
Operation and installation
Temperature range
-55 … 200 °C
Interfaces
Connection type (sensor)
KIAG 10-32 pos.
Connection type (amplifier)
TNC pos.
Dimensions and materials
Predefined cable length
0.5 m
Green, single-wire, high insulation, PFA based cable (ø2 mm) for sensors with KIAG 10-32 neg. int. connector Charge mode, high impedance piezoelectric measurement demands highly insulated coaxial cables and connectors to ensure an insulation resistance greater than 1013 Ω throughout the measuring chain. Only low noise coaxial cables that produce very little triboelectricity during movement may be used. The connectors must be robust, sealed and resistant to dirt.
Loading