Multicomponent dynamometer MicroDyn, 500 N, cover plate 30x30 mm / 9109AA

Multicomponent dynamometer MicroDyn, 500 N, cover plate 30x30 mm
9109AA
18034487
  • Piezoelectric multicomponent dynamometer with maximum forces Fx, Fy, Fz ±500 N
  • Cover plate 30x30 mm
  • Natural frequency fn (x), fn (y), fn (z) >15 kHz
  • Fischer 9-pin flange connector
 
 
Preloaded sensorNoMaximum measuring range0.5 kNCalibrated measuring range0 … 500 N (Fx, Fy, Fz 100%)Average Sensitivity Fz≈–20 pC/NCrosstalk Fx -> Fz≤±2%Crosstalk Fz -> Fx≤±2%Crosstalk Fy -> Fz≤±2%Capacitance X2+4 Y1+3≈120 pFCentrical Overload Mx My±30 NmSensitivityFx: -12.5 pC/N, Fy: -12.5 pC/N, Fz: -20 pC/NOperating temperature range-20 … 70 °CInsulation resistance>10^13 ΩApplicationsCutting processes and machining development
Measuring range-0.5 … 0.5 kNForce sensor typeMulticomponent dynamomometerAverage Sensitivity Fx, Fy≈–12.5 pC/NCrosstalk Fx -> Fy≤±4%Crosstalk Fy -> Fx≤±4%Crosstalk Fz -> Fy≤±2%Capacitance Z≈240 pFCapacitance X1 X3 Y2 Y4≈60 pFCentrical Overload Mz±60 NmThreshold<0.002 NDegree of protection EN 60529IP67Weight1.04 kg
This is a multicomponent dynamometer for measuring the three orthogonal components of a force and the torque Mz. The very low threshold and the high sensitivity allow even the smallest forces to be measured. With a natural frequency higher than 15 kHz in all three axes, highly dynamic forces can be recorded with extremely high accuracy.